Request For Quote | Model # | Type | Total Outlets | Power Capacity kW | Voltage | Current (A) | Current Rated (A) | Phase | Plug Type | Description | Branch Monitoring | Outlet Monitoring | Dimensions | Mounting | PRO2 | Input Monitoring | Alt Phase |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
STV-4503K | Switched | 30 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4522D | Switched | 48 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6541M | Switched POPS | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | 230V 56 Series 56P332 | Switched POPS PRO2, Per Out... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4503Z | Switched | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4522E | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541K | Switched | 24 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4522L | Switched | 48 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541J | Switched | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC 230V/16A 2P+PE 6Hr | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-5542L | Smart POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | PRO2 Smart POPS PRO2 Master... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523A | Switched | 48 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-20P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-5542D | Smart POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L15-20P | PRO2 Smart POPS PRO2 Master... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523C | Switched | 48 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4541B | Switched | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | NEMA L6-20P | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-5542E | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L15-30P | PRO2 Smart POPS PRO2 Master... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-4523K | Switched | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4540C | Switched | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1 with PIPS (Pe... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4523D | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542M | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched POPS/PIPS PRO2 (Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-5542M | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | PRO2 Smart POPS PRO2 Master... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
CS-12HD2G454A3 | Smart | 12 | 6.6 | 208 | 20 | 16 | 1-Phase (L-L) | NEMA L6-20P | Smart PDU with PIPS (Per In... | None | None | 2U Horizontal | PIPS | false | |||
STV-4522M | Switched | 48 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542L | Switched POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched POPS/PIPS PRO2 (Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
CS-12HD2C454A3 | Smart | 12 | 10.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart PDU with PIPS (Per In... | None | None | 2U Horizontal | PIPS | false | |||
STV-4523J | Switched | 48 | 11.1 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542E | Switched POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched POPS (Per Outlet P... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
CS-12HDEJ454A3 | Smart | 12 | 7.3 | 230 | 16 | 16 | 1-Phase (L-N) | IEC 230V/16A 2P+PE 6Hr | Smart PDU with PIPS (Per In... | None | None | 2U Horizontal | PIPS | false | |||
CSG-24V2C417A1 | Smart POPS | 24 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Smart POPS/PIPS PDU, Per Ou... | Sense | POPS | 0U Vertical | PIPS | false | |||
STV-4523Z | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-6542D | Switched POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched POPS (Per Outlet P... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
CS-12HDEK454A3 | Smart | 12 | 14.7 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Smart PDU with PIPS (Per In... | None | None | 2U Horizontal | PIPS | false | |||
STV-6521D | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | PRO2 Switched POPS, 0U, 48 ... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6521Y | Switched POPS | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | PRO2 Switched POPS, 0U, 48 ... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
CSG-24V2A415A1 | Smart POPS | 24 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Smart POPS/PIPS PDU, Per Ou... | Sense | POPS | 0U Vertical | PIPS | false | |||
CSG-24VEA415A1 | Smart POPS | 24 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Smart POPS/PIPS PDU, Per Ou... | Sense | POPS | 0U Vertical | PIPS | false | |||
STV-4522V | Switched | 48 | 10.0 | 208 | 30 | 30 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO2 with PIPS (Pe... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1W24VS-YCFA13C9 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-YCFA11C9 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-YBFA11C9 | Switched | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DEFA13A1 | Switched | 24 | 12.5 | 208 | 50 | 35 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DEFA11A1 | Switched | 24 | 12.5 | 208 | 50 | 35 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C-12V1-C20M | Metered | 12 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Metered PDU, 0U, 12 x NEMA ... | None | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DCFA13A1 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C-12V1-L30M | Metered | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Metered PDU, 0U, 12 x NEMA ... | None | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DCFA11A1 | Switched | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
C1W24VS-DBFA11A1 | Switched | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Switched PRO1, 0U, 18 x IEC... | Sense | None | 0U Vertical | Current (A) | false | |||
STV-4526Y | Switched | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched PRO2, 0U, (36) IEC... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4526V | Switched | 48 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched PRO2, 0U, (36) IEC... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4526D | Switched | 48 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Switched PRO2, 0U, (36) IEC... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1W16VS-0AFA17AC | Switched | 16 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
STV-6501M | Switched POPS | 30 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | 230V 56 Series 56P332 | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
C1W16VS-2CFA17AC | Switched | 16 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
C1W16VS-EPFA17AC | Switched | 16 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4525Z | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO2, 0U, 36xIEC C... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4525D | Switched | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO2, 0U, 36xIEC C... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1WG24VT-DQBA54F2 | Switched POPS | 24 | 17.3 | 208 | 60 | 48 | 3-Phase Delta (L-L) | 208V Delta 60A IEC 60309 3P+G 9Hr | Switched POPS PDU, 0U, 24 O... | Sense | POPS | 0U Vertical | Current (A) | false | |||
C1WG24VT-YQBA54F2 | Switched POPS | 24 | 17.3 | 208 | 60 | 48 | 3-Phase Wye (L-L) | 208V Wye 60A IEC 60309 3P+N+G 9Hr | Switched POPS PDU, 0U, 24 O... | Sense | POPS | 0U Vertical | Current (A) | false | |||
C1WG24VT-DFBA54F2 | Switched POPS | 24 | 14.4 | 208 | 50 | 40 | 3-Phase Delta (L-L) | CS8365 3P+G 50A | Switched POPS PDU, 0U, 24 O... | Sense | POPS | 0U Vertical | Current (A) | false | |||
STV-4525J | Switched | 48 | 22.0 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched PRO2, 0U, 36xIEC C... | Current (A) | None | 0U Vertical | PIPS | false | |||
C1W16VS-OAFA17AC | Switched | 16 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 100-240V Inlet | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
STV-2001C | Metered | 30 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Metered PDU, 0U, (24) IEC C... | None | None | 0U Vertical | Current (A) | false | |||
STV-2001K | Metered | 30 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Metered PDU, 0U, (24) IEC C... | None | None | 0U Vertical | Current (A) | false | |||
STV-6501G | Switched POPS | 30 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Switched POPS/PIPS PRO2, Pe... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
C-16HFE-P32 | FSTS | 16 | 7.3 | 230 | 32 | 32 | 1-Phase (L-N) | IEC 230V/32A 2P+PE 6Hr | Fail-Safe Transfer Switch, ... | None | None | 2U Horizontal | Current (A) | false | |||
C-16HF2-L30 | FSTS | 16 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Fail-Safe Transfer Switch, ... | None | None | 2U Horizontal | Current (A) | false | |||
C-16HF1-L30 | FSTS | 16 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Fail-Safe Transfer Switch, ... | None | None | 2U Horizontal | Current (A) | false | |||
C-16HF2-C20 | FSTS | 16 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Fail-Safe Transfer Switch, ... | None | None | 2U Horizontal | Current (A) | false | |||
CSG-24VDE425A1 | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Delta (L-L) | NEMA L15-30P | Smart POPS (Per Outlet Powe... | None | POPS | 0U Vertical | PIPS | false | |||
C-16HF1-C20 | FSTS | 16 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Fail-Safe Transfer Switch, ... | None | None | 2U Horizontal | Current (A) | false | |||
STV-6525Z | Switched POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched POPS PRO2 with PIP... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
PTTS-H008-0-02M | FSTS | 8 | 3.3 | 208 | 16 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Sentry Fail Safe Transfer S... | None | None | 1U Horizontal | None | false | |||
STV-6525K | Switched POPS | 48 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | Switched POPS PRO2 with PIP... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
STV-6525J | Switched POPS | 48 | 11.1 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | Switched POPS PRO2 with PIP... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
CSG-24VYL425C9 | Smart POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Smart POPS (Per Outlet Powe... | None | POPS | 0U Vertical | PIPS | false | |||
C-16HFE-C20 | FSTS | 16 | 3.6 | 230 | 16 | 16 | 1-Phase (L-N) | IEC C20 230V Inlet | Fail-Safe Transfer Switch, ... | None | None | 2U Horizontal | Current (A) | false | |||
STV-6525D | Switched POPS | 48 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched POPS PRO2 with PIP... | Current (A) | POPS | 0U Vertical | PIPS | false | |||
PTTS-H008-O-02M | FSTS | 8 | 1.9 | 120 | 16 | 16 | 1-Phase (L-L) | IEC C20 100-240V Inlet | Sentry Fail Safe Transfer S... | None | None | 1U Horizontal | None | false | |||
CB-12H1-C20 | Basic | 12 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | Basic PDU, 12 NEMA 5-20R ou... | None | None | 1U Horizontal | None | false | |||
CB-12H2-L630 | Basic | 12 | 5.0 | 208 | 30 | 24 | 1-Phase (L-L) | NEMA L6-30P | Basic PDU, 12 IEC C13 outle... | None | None | 1U Horizontal | None | false | |||
CB-26VOAE01F6 | Basic | 26 | 1.9 | 120 | 16 | 16 | 1-Phase (L-N) | IEC C20 100-240V Inlet | Basic PDU, (24) IEC C13 + (... | None | None | 0U Vertical | None | false | |||
CB-12H2-C20 | Basic | 12 | 3.3 | 208 | 20 | 16 | 1-Phase (L-L) | IEC C20 200-240V Inlet | Basic PDU, 12 IEC C13 outle... | None | None | 1U Horizontal | None | false | |||
C1W24VS-1AFA25A5 | Switched | 24 | 1.9 | 120 | 20 | 16 | 1-Phase (L-N) | IEC C20 100-120V Inlet | PRO1 Switched PDU with PIPS... | Sense | None | 0U Vertical | PIPS | false | |||
CB-12H1-L530 | Basic | 12 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | Basic PDU, 12 NEMA 5-20R ou... | None | None | 1U Horizontal | None | false | |||
CSG-24VYM427C9 | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS (Per Outlet Powe... | None | POPS | 0U Vertical | PIPS | false | |||
STV-3534A | Smart | 30 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-20P | PRO1 Smart Master PIPS, 0U,... | None | None | 0U Vertical | PIPS | false | |||
STV-3534C | Smart | 30 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | PRO1 Smart Master PIPS, 0U,... | None | None | 0U Vertical | PIPS | false | |||
STV-3534D | Smart | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | PRO1 Smart Master PIPS, 0U,... | None | None | 0U Vertical | PIPS | false | |||
STV-3534J | Smart | 30 | 11.0 | 400 | 16 | 16 | 3-Phase Wye (L-N) | 230/400V Wye 16A IEC 60309 3P+N+PE 6Hr | PRO1 Smart Master PIPS, 0U,... | None | None | 0U Vertical | PIPS | false | |||
STV-3534K | Smart | 30 | 22.0 | 400 | 32 | 32 | 3-Phase Wye (L-N) | 230/400V Wye 32A IEC 60309 3P+N+PE 6Hr | PRO1 Smart Master PIPS, 0U,... | None | None | 0U Vertical | PIPS | false | |||
STV-3534Z | Smart | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | PRO1 Smart Master PIPS, 0U,... | None | None | 0U Vertical | PIPS | false | |||
C1W24VS-1DFA25A5 | Switched | 24 | 2.8 | 120 | 30 | 24 | 1-Phase (L-N) | NEMA L5-30P | PRO1 Switched PDU with PIPS... | Sense | None | 0U Vertical | PIPS | false | |||
C1W24VT-5PPA17AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
CSG-24VDD425A1 | Smart POPS | 24 | 5.7 | 208 | 20 | 16 | 3-Phase Delta (L-L) | NEMA L15-20P | Smart POPS (Per Outlet Powe... | None | POPS | 0U Vertical | PIPS | false | |||
C1W24VT-5CPA17AC | Switched | 24 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | NEMA L22-30P | Switched PRO1, PIPS (Per In... | Sense | None | 0U Vertical | PIPS | false | |||
STV-4503C | Switched | 30 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | 240/415V Wye 20A IEC 60309 3P+N+G 6Hr | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4503A | Switched | 30 | 11.5 | 415 | 20 | 16 | 3-Phase Wye (L-N) | NEMA L22-20P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
CSG-24VYM425C9 | Smart POPS | 24 | 8.6 | 208 | 30 | 24 | 3-Phase Wye (L-L) | NEMA L21-30P | Smart POPS (Per Outlet Powe... | None | POPS | 0U Vertical | PIPS | false | |||
STV-4502L | Switched | 30 | 5.7 | 208 | 20 | 16 | 3-Phase Wye (L-L) | NEMA L21-20P | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
STV-4503D | Switched | 30 | 17.3 | 415 | 30 | 24 | 3-Phase Wye (L-N) | 240/415V Wye 30A IEC 60309 3P+N+G 6Hr | Switched PIPS PRO2, Per Inp... | Current (A) | None | 0U Vertical | PIPS | false | |||
48DCWB-08-2X100-B0NB | -48 VDC | 8 | 9.6 | -48 | 200 | 200 | DC | Terminals | Sentry -48 VDC Remote Power... | None | Current (A) | 2U Horizontal | None | false |